Re: Scaling with memory & disk planning
От | Scott Marlowe |
---|---|
Тема | Re: Scaling with memory & disk planning |
Дата | |
Msg-id | Pine.LNX.4.33.0205301622060.15639-100000@css120.ihs.com обсуждение исходный текст |
Ответ на | Re: Scaling with memory & disk planning (terry@greatgulfhomes.com) |
Список | pgsql-general |
On Thu, 30 May 2002 terry@greatgulfhomes.com wrote: > What is RAID1 with > 2 drives??? Just that. A mirror set that writes all changes to all drives. It costs more for writes, but runs faster for reads, so it's not a good idea to use one in a heavily written environment, but it really flies for heavy read setups, like data mining or CRM stuff. Plus, a single drive failure is no big deal, you just replace it at your leisure, since you're still fully redundant. This means you could do crazy things like build 9 disks into a RAID 0+1 by making three sets of RAID 1 with three drives, and then put all three together to make the RAID 0. Very good read speeds under heavy loads, and fairly good write speeds as well. You could run a fairly large database on a setup of 9 36 Gig ultra SCSI drives like this, and get some nice throughput, and have it be VERY redundant. I.e. ANY two drives could fail, and you'd still be up, and if the two drives that failed were in different RAID1s, you'd still be fully redundant. Crazy stuff.