Re: HS/SR and smart shutdown
От | Robert Haas |
---|---|
Тема | Re: HS/SR and smart shutdown |
Дата | |
Msg-id | 603c8f071001201758t5adce3bfq13ded174744d62f@mail.gmail.com обсуждение исходный текст |
Ответ на | Re: HS/SR and smart shutdown (Tom Lane <tgl@sss.pgh.pa.us>) |
Список | pgsql-hackers |
On Wed, Jan 20, 2010 at 8:56 PM, Tom Lane <tgl@sss.pgh.pa.us> wrote: > Robert Haas <robertmhaas@gmail.com> writes: >> On Wed, Jan 20, 2010 at 8:44 PM, Josh Berkus <josh@agliodbs.com> wrote: >>> Well, as long as streaming rep is running, you can't do a smart shutdown >>> ... smart shutdown seems to treat the walreciever as a client >>> connection. At the very least, this should be in the documentation. > >> How hard is it to fix? > > I think the first question is do we *want* to fix it, or is it > appropriate behavior? > > If the master shuts down, will the slaves try to fail over to become > masters? When the master restarts, will the slaves automatically > reconnect? If these questions have the wrong answers, shutting down the > master isn't something to be done lightly, and automatically > disconnecting slaves would be a real bad idea. I thought the scenario in question was that someone wanted to manually shut down the slave. Am I misunderstanding? ...Robert
В списке pgsql-hackers по дате отправления: