>>> The SQL spec doesn't allow unconstrained lengths for these types >>> so it gives no guidance about what to display in the information_schema >>> views. Any opinions? >> >> If there isn't a set scale for the type, then NULL would probably make the >> most sense. After more thought I like returning NULL for both precision and scale in the case of unconstrained numeric columns. Any other value is arbitrary. In particular, the 1000 cited in the docs is *very* arbitrary, and I don't think it actually constrains what you can store, only what you can declare as a column precision. [tries it...] Yup, I can store "power(10.0, 10000)" in an unconstrained numeric column. It seems to fail around 10^140000 but I'm not sure where that limit is coming from exactly... regards, tom lane