Re: Changing ids conflicting with serial values?
От | Joshua D. Drake |
---|---|
Тема | Re: Changing ids conflicting with serial values? |
Дата | |
Msg-id | 436988C2.5070207@commandprompt.com обсуждение исходный текст |
Ответ на | Changing ids conflicting with serial values? (Steven Brown <swbrown@ucsd.edu>) |
Список | pgsql-general |
Steven Brown wrote: > When I change an id (primary key serial) in a table, the next value > returned by the sequence for the id can conflict with that id (e.g., > change the id to be id + 1). MySQL seems to handle this transparently > by skipping conflicting values, but with PostgreSQL I get primary key > conflicts. It seems rather bad if a user can modify an id in a row > and cause failures for all future inserts - it's just too fragile. > What's the proper way to handle this in PostgreSQL? Why are your users modifying the key in the first place? Typically in an environment where you have an autoincrementing key, that key is static. Meaning it does not change for a particular row. Thus it never conflicts. Could you perhaps explain a little further what it is you are trying to do? Sincerely, Joshua D. Drake > > > ---------------------------(end of broadcast)--------------------------- > TIP 6: explain analyze is your friend -- The PostgreSQL Company - Command Prompt, Inc. 1.503.667.4564 PostgreSQL Replication, Consulting, Custom Development, 24x7 support Managed Services, Shared and Dedicated Hosting Co-Authors: plPHP, plPerlNG - http://www.commandprompt.com/
В списке pgsql-general по дате отправления: