Re: Test for trigger condition accessing system attributes
От | Heikki Linnakangas |
---|---|
Тема | Re: Test for trigger condition accessing system attributes |
Дата | |
Msg-id | 16d84c11-3dd9-c13d-1692-85ada401f05a@iki.fi обсуждение исходный текст |
Ответ на | Test for trigger condition accessing system attributes (Ashutosh Bapat <ashutosh.bapat@enterprisedb.com>) |
Ответы |
Re: Test for trigger condition accessing system attributes
|
Список | pgsql-hackers |
On 10/05/18 11:58, Ashutosh Bapat wrote: > Hi, > I was investigating the cases when the system attributes are accessed > beyond the scans. After investigating set_plan_references(), I thought > that we never access system attributes beyond scans. This lead me to > assume that EEOP_INNER/OUTER_SYSVAR are not needed since we do not > access system attributes from an inner or outer slot. I removed the > defintions and code using those and ran regression. All the tests > passed. So, I was about to conclude that my assumption is correct. But > then looking at TriggerEnabled() I realised that we also (ab?)use > INNER/OUTER Vars for OLD/NEW tuples for trigger condition. If the WHEN > condition in CREATE TRIGGER command refers to a system attribute, we > will end up having INNER/OUTER var refering a system attribute, thus > exercising code for EEOP_INNER/OUTER_SYSVAR. > > Here's patch containing a testcase exercizing that code using > EEOP_INNER/OUTER_SYSVAR. Pushed with some small changes. Thanks! - Heikki
В списке pgsql-hackers по дате отправления: