On 11-Jul-07, at 10:05 AM, Gregory Stark wrote: > "Dave Cramer" <pg@fastcrypt.com> writes: > >> Assuming we have 24 73G drives is it better to make one big >> metalun and carve >> it up and let the SAN manage the where everything is, or is it >> better to >> specify which spindles are where. > > This is quite a controversial question with proponents of both > strategies. > > I would suggest having one RAID-1 array for the WAL and throw the > rest of the This is quite unexpected. Since the WAL is primarily all writes, isn't a RAID 1 the slowest of all for writing ? > drives at a single big array for the data files. That wastes space > since the > WAL isn't big but the benefit is big. > > If you have a battery backed cache you might not need even that. > Just throwing > them all into a big raid might work just as well. Any ideas on how to test this before we install the database ? > > -- > Gregory Stark > EnterpriseDB http://www.enterprisedb.com >
В списке pgsql-performance по дате отправления: