In order to keep the new driver from locking in a POSIX thread environment, I had to change connection.c to init the connection mutex (Line 1259). The driver appears to work now. Why this was an issue I am not sure, because although there are changes to connection.c to add the usage of this mutex, my observation from the 0100 version seem to show it too was used before it was intialized, and it seemed to work fine. Any Comments? 1251 if (SOCK_get_errcode(sock) != 0) 1252 { 1253 CC_set_error(self, CONNECTION_COULD_NOT_SEND, "Could not send Query to backend"); 1254 CC_on_abort(self, NO_TRANS | CONN_DEAD); 1255 return NULL; 1256 } 1257 1258 INIT_CONN_CS(self); 1259 ENTER_CONN_CS(self); 1260 SOCK_put_char(sock, 'Q'); 1261 if (SOCK_get_errcode(sock) != 0) 1262 { 1263 CC_set_error(self, CONNECTION_COULD_NOT_SEND, "Could not send Query to backend"); 1264 CC_on_abort(self, NO_TRANS | CONN_DEAD); 1265 RETURN_AFTER_LEAVE_CS(self, NULL); 1266 } Eric Eric Hallander Tellium Inc. 2 Crescent Place Oceanport, NJ 07757 (732) 483-2922 (732) 923-9804 FAX <mailto:ehallander@tellium.com> (Work) <mailto:7323101830@mobile.att.net> (Cell Phone 150 chars total) <http://www.tellium.com/> ********************************************************************** This email and any files transmitted with it are confidential and intended solely for the use of the individual or entityto whom they are addressed. Any review, retransmission or other use of this communication by any person or entity otherthan the intended recipient is prohibited. If you believe that you have received this email in error please notify thesender by return electronic mail and delete all copies of this communication. **********************************************************************
Вложения
В списке pgsql-odbc по дате отправления: